7. PROGRAMMING
WARNINGS! Programming must be done when the motor is not in movement, after having correctly
set the limit switches and having checked the direction of rotation of the motor.
7.1 AUTOMATIC CLOSING MODE
The control includes, among its functions, the automatic closing after a set time.
The automatic closing activates by programming the pause time and by choosing the "impulse"
operating mode (DIP 2 in OFF). When the dead-man logic is active while closing, the automatic closing
is excluded (DIP 2 in ON).
In order to program the pause time it is necessary:
1. To put DIP 5 and 6 in OFF
2. To put DIP 5 in ON. The green LED will switch off and make a short flash every second.
3. Wait for the pause time you want to program (the time must be greater than 5 seconds, for a
maximum of 4 minutes)
4. After the required time replace the DIP 5 in OFF
If programming is correct, the green LED will flash quickly and then remains lit.
ADDITIONAL NOTE: The time count for the automatic closing starts when the opening movement
is interrupted by the START/STOP command or the intervention of the limit switch in opening; the
counting of the pause is notified via a short cut off of the green LED every 3 seconds.
While in pause, a START/STOP control excludes the automatic closing; a further START/STOP control
closes the door. By pushing the STOP control the automatic closing is excluded.
The automatic reclosure is excluded (even if programmed) if:
• a safety system intervenes (safety stop, photocell, bar, motor thermal efficiency etc.)
• the dead-man logic is activated in closing
• a closing movement is interrupted.
7.2 CANCELLATION OF THE AUTOMATIC CLOSING MODE
This procedure clears the pause time and then excludes the automatic closing.
1. Put DIP 5 and 6 in OFF
2. Put DIP 5 in ON and within 3 seconds put it again in OFF.
If cancellation has been accomplished correctly, the red LED will flash quickly and then switch off.
Then the green LED will switch on steady.
7.3 PROGRAMMING OF WORKING TIME
The work time is the time it takes to perform a complete opening or closing operation. By performing
this procedure the board automatically learns the stroke. Without programming, the working time
lasts 30 sec.
ATTENTION: During the programming procedure ensure that no obstacle activates the safety devices
(photocells or safety edges) and stops the movement of the door. If that happens, it is necessary to
proceed with a new programming cycle of the working time (close the current programming, perform
the RESET and proceed with a new cycle).
In order to program the working time, you must:
1. Test the motor phases and check that the limit switches are calibrated and connected properly! If
during the procedure the safety systems intervene, the movement of the motor stops.
2. Place the door halfway.
3. Put DIP 5 and 6 in OFF.
4. Put DIP 6 in ON. The red LED will switch on.
5. Give a START/STOP signal (terminal 7), the door starts to open. When opening is complete send a
new START/STOP signal.
6. Give a START/STOP signal (terminal 7), the door starts to close. When closing is complete send a
new START/STOP signal.
7. Set DIP 6 in OFF. The red LED will switch off indicating the end of the programming procedure.
NOTE: In order to ensure the complete closing and opening under all conditions, the control unit
automatically adds 4 seconds to the programmed time.
15