Descargar Imprimir esta página

NOCO Genius 5AU Guia Del Usuario página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Mode
Explanation
In Standby mode, the charger is not charging or providing any power to the battery. Energy Save is activated during this mode, drawing
microscopic power from the electrical outlet. Canbus is enabled in Standby mode. When in Standby, the orange Standby LED will illuminate.
Standby
No Power
For charging 12-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. When selected, the 12V white LED will
illuminate.
14.5V | 5A | Up To 120Ah Batteries
For charging 12-volt AGM batteries. When selected, the 12V AGM white LED will illuminate.
14.8V | 5A | Up To 120Ah Batteries
For charging 12-volt lithium-ion batteries, including lithium iron phosphate. When selected, the 12V Lithium blue LED will illuminate. For use on
batteries with Battery Management Systems (BMS) only.
14.6V | 5A | Up To 120Ah Batteries
For charging 6-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. When selected, the 6V white LED will
illuminate.
Press & Hold (3
Seconds)
7.25V | 5A | Up To 120Ah Batteries
Force Mode
For charging 6-volt advanced AGM batteries, which requires a higher than normal charging voltage. When selected, a white LED will illuminate.
Press & Hold (5
Seconds)
5A | Up To 120Ah Batteries
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED
will illuminate and flash.
16.5V | 5A | Any Capacity
(Peak Voltage Measured At 25°C, Amperage Rating Is Bulk Amperage When Above 0°C)
[From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery]

Publicidad

loading

Este manual también es adecuado para:

Genius5auGenius5