Installation instructions
Step 5. Installing the conduit
Remove the conduit connection plate from the rear of the drawer body and rotate
it as shown below.
The conduit hole (1⅛") must be used.
1⅜"
1⅛"
1⅜"
1⅛"
1.
Prepare the conduit cord shown in Figure 1.
2.
Install the conduit cord as shown in Figure 2.
For conduit installations, insert the strain relief (not included) into the conduit hole
(1⅛"). Then thread the conduit cord through the body of the strain relief and fasten
the ring. Reinstall the bracket.
22 English
Install_DOP36P86DLS_DG68-01106E-00_EN+MES+CFR.indb 22
Installing a 3-wire conduit
•
•
Strain relief
Ring
Body
Ground
strap
Figure 2
4 wire
⅜"
3½"
Conduit
connection
1"
plate
3 wire
⅜"
3½"
Knockout
1"
surface
Figure 1
Aluminum building wire may be used but it must be rated for the correct
amperage and voltage to make the connection. Connect wires according to
Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring
practices and local codes.
1.
2.
Red
Red
Wire tips
White
White
Black
Black
3.
Neutral
terminal
4.
5.
Loosen the 3 lower terminal screws
from the terminal block.
Insert the center bare wire (white/
neutral) tip through the bottom center
terminal block opening. On certain
models, the wire will need to be
inserted through the ground strap
opening and then into the bottom
center block opening.
Insert the two side bare wire tips into
the lower left and the lower right
terminal block openings.
Tighten the screws until the wire is
firmly secured (35 to 50 inch-lbs.). Do
not over-tighten the screws since it
could damage the wires.
Go to Step 6 on page 23 and proceed
with the installation.
2020-07-01 오후 3:44:09