Connect Water Supply
Read all directions before you begin.
IMPORTANT:
Plumbing shall be installed in accordance with the
International Plumbing Code and any local codes and
ordinances.
The gray water tubing on the back of the refrigerator (which is
used to connect to the household water line) is a PEX
(cross-linked polyethylene) tube. Copper and PEX tubing
connections from the household water line to the refrigerator
are acceptable, and will help avoid off-taste or odor in your ice
or water. Check for leaks.
If PEX tubing is used instead of copper, we recommend the
following Whirlpool Part Numbers:
W10505928RP (7 ft [2.14 m] jacketed PEX),
8212547RP (5 ft [1.52 m] PEX), or
W10267701RP (25 ft [7.62 m] PEX).
Install tubing only in areas where temperatures will remain
above freezing.
TOOLS NEEDED:
Gather the required tools and parts before starting installation.
Flat-blade screwdriver
⁷⁄₁₆" and ¹⁄₂" open-end wrenches or two adjustable wrenches
¹⁄₄" nut driver
Connect to Water Line
IMPORTANT: If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
Style 1 (Recommended)
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Use a quarter-turn shutoff valve or the equivalent, served by a
¹⁄₂" copper household supply line.
NOTE: To allow sufficient water flow to the refrigerator, a
minimum ¹⁄₂" size copper household supply line is
recommended.
D
A. Bulb
C. Copper tubing (to refrigerator)
B. Nut
D. Household supply line (½" minimum)
4. Now you are ready to connect the copper tubing to the shutoff
valve. Use ¹⁄₄" (6.35 mm) O.D. (outside diameter) soft copper
tubing to connect the shutoff valve and the refrigerator.
Ensure that you have the proper length needed for the job.
Be sure both ends of the copper tubing are cut square.
All manuals and user guides at all-guides.com
5. Place the free end of the tubing into a container or sink, and
6. Bend the copper tubing to meet the water line inlet, which is
Style 2
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
3. Locate a
4. Determine the length of copper tubing you need. Measure
5. Using a cordless drill, drill a ¹⁄₄" (6.35 mm) hole in the cold
A
B
C
6. Fasten the shutoff valve to the cold water pipe with the pipe
7. Slip the compression sleeve and compression nut on the
8. Place the free end of the tubing in a container or sink, and turn
Slip compression sleeve and compression nut onto
copper tubing as shown. Insert end of tubing into outlet
end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not
overtighten.
A
B
A. Compression sleeve
B. Compression nut
turn on main water supply to flush out tubing until water is
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve, to avoid possible
water valve malfunction.
located on the back of the refrigerator cabinet as shown.
Leave a coil of copper tubing to allow the refrigerator to be
pulled out of the cabinet or away from the wall for service.
enough to clear line of water.
¹⁄₂
¹⁄₄
" (1.27 cm) to 1
pipe near the refrigerator.
IMPORTANT:
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from
the drill and normal sediment from collecting in the valve.
from the connection on the lower rear corner of refrigerator to
the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use ¹⁄₄"
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both
ends of copper tubing are cut square.
water pipe you have selected.
G
F
E
D
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
clamp. Be sure the outlet end is solidly in the ¹⁄₄" (6.35 mm)
drilled hole in the water pipe and that the washer is under the
pipe clamp. Tighten the packing nut. Tighten the pipe clamp
screws slowly and evenly so the washer makes a watertight
seal. Do not overtighten, or you may crush the copper tubing.
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw the compression
nut onto outlet end with adjustable wrench. Do not
overtighten.
ON the main water supply. Flush the tubing until water is clear.
Turn OFF the shutoff valve on the water pipe. Coil the copper
tubing.
C
C. Copper tubing
" (3.18 cm) vertical cold water
A
B
C
E. Compression sleeve
F. Shutoff valve
G. Packing nut