Recheck the polarity of all cables to ensure that the correct connections have been made
Turn on the disconnect switch or circuit breaker
Turn the power inverter ON. Set the display to show Input Voltage. The display should provide a detailed
reading of your power source battery(ies) voltage
If the power inverter does not turn ON or does not display input voltage, check your battery condition and all
connections and repeat.
Connect the AC Cables
Before connecting any device to be powered by the power inverter to an AC receptacle on the power inverter, ensure
that both the device and the power inverter are turned OFF. Plug the device into the power inverter's AC
receptacle. If you run the AC cable of any device through a wall or other barrier, or near any sharp or rough edges,
always be sure to protect the AC cable from chaffing. When disconnecting any device powered by the power
inverter, always pull on the plug and never on the wire. NEVER operate a device with a damaged power cord.
Junction Block Output Connection
The power inverter is equipped with a junction block output option for hardwire output connections. As always, care
must be taken to properly configure your output via this connection. Please refer to "Installation Code Compliance"
and follow all local, state and national codes to ensure your installation is complaint with such codes.
Power Inverter Installation Schematic
INVERTER
SOLAR Power Inverter USER'S MANUAL
POSITIVE
ON
OFF
FUSE OR
CIRCUIT
BREAKER
GROUND TO
VEHICLE
CHASSIS
11
DISCONNECT
SWITCH
DEEP-CYCLE
AUXILIARY
BATTERY
GROUND TO
VEHICLE
CHASSIS
DEEP-CYCLE
AUXILIARY
BATTERY
TO VEHICLE
VEHICLE
STARTING
BATTERY
GROUND TO
VEHICLE
CHASSIS
ISOLATOR
FROM ALTERNATOR
OR CHARGER

Publicidad

loading