unit may contain wa ter condensation and oil mist. Do not spray
un fil tered air at an item that could be damaged by moisture.
Some air tools and accessories may require filtered air. Read the
in struc tions for the air tools and accessories.
How to Start
1.
Turn the Auto/Off switch to "Auto" and allow tank pressure to
build. Motor will stop when tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and turn clockwise to increase pres-
sure. When the desired pressure is reached push knob in to
lock in place.
IMPORTANT: When using regulator and other accessories refer to
the manufacturers instructions.
WARNING: Risk of bursting. If any unusual noise or vibration
is noticed, stop the compressor immediately and have it checked
by a trained service technician.
The compressor is ready for use.
Shut-down (Fig. 1)
1. Move Auto/Off switch to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
2. Pull the regulator knob out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push
knob in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and
weaken the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
16
FIG. 3
OFF
AUTO
OPEN
CLOSE

Publicidad

loading