Descargar Imprimir esta página

Facom V.347F Manual Original página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
PLACING THE MACHINE IN SERVICE
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
3
Model
Chuck capacity
mm
V.347F
Ø 6
Model
Free speed
rpm
V.347F
20000
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 rUE gUStAVE EIFFEL - BP 99 - 91 423 MOrANgIS CEDEX FrANCE, DECLArE UNDEr OUr OWN rESPONSIBILItY tHAt tHE
PrODUCt V.347F – FACOM PNEUMATIC ANGLE GRINDER - 6 MM COLLET
- IS IN CONFOrMItY WItH tHE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFOrMItY WItH tHE PrOVISIONS OF tHE HArMONISED EUrOPEAN StANDArD EN ISO 11148-9:2011
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-12:2012
LUBrIFICAtION
Motor power
rating
kW
0,25
Air consumption
l/min
113
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
1
4
Noise level dB(A)
Pressure dB(A)
Power dB(A)
k*
90,9
3
101,9
Working
Weight
pressure
bar
kg
6,2
0,53
EMERGENCY
GATE VALVE
2
5
Pressure dB(C)
k*
k*
3
105
3
Dimensions
mm
160 x 73 x 27
F
ACOM QUALItY MANAgEr
Vibrations level
m/s
2
k**
1,52
0,53
20.01.2010

Publicidad

loading