Switch action
CAUTION:
Before inserting the battery cartridge into the tool,
•
always check to see that the switch trigger
actuates properly and returns to the "OFF" position
when released.
1
012491
For your safety, this tool is equipped with a dual
switching system. To turn on the tool, press the lock-off
button and triggers A and B. Release either one of the
Red Indicator Light
Light Blinks
Light Stays On
(See Note 1 below)
Note 1: When attempting to switch the tool on, the indicator light may continue to come on
due to the tool and/or the battery pack being too warm.
The battery tool and battery pack will need to be allowed to cool down before
further use.
013094
OPERATION
CAUTION:
Be careful not to accidentally contact a metal fence
•
or other hard objects while trimming. The blade will
break and may cause serious injury.
Overreaching with a hedge trimmer, particularly
•
from a ladder, is extremely dangerous. Do not work
1. Switch trigger A
3
2
2. Switch trigger B
3. Lock-off button
This indicates the battery
level is getting low.
The remaining battery capacity
is too low and the tool will not
operate.
The battery protection system
has been activated due to the
tool being overloaded.
two pressed triggers to turn off. The sequence of
switching is unimportant as the tool only starts when
both switches are activated.
Indication lamp
012480
Running the tool allows the indication lamp to show the
battery cartridge capacity status.
When the tool is also overloaded and has stopped
during operation, the lamp lights up in red.
Refer to the following table for the status and action to
be taken for the indication lamp.
Condition
Recharge the battery cartridge.
Remove and recharge the
battery.
Release the switch trigger on
the tool and stop the application
that caused the tool to become
overloaded.
Then pull the switch trigger again
to restart.
from anything wobbly or infirm.
6
1. Indication lamp
1