mode)
- place a pail under each faucet and drain all product from
bowls
- set all control switches to the 0 position.
5. 3. 1 DISASSEMBLY
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source.
1 - Remove cover from the bowl.
2 - Remove the bowl by lifting its faucet side up and off the
fastening hooks (see figure 6) and slide it out (see figure
7).
3 - Slide the outer spiral out (see figure 8) and then the inside
figure 6
figure 7
auger (see figure 9).
4 - Remove the bowl gasket from its seat (see figure 10).
MT UL AF
figure 8
figure 9
figure 10
7