TROUBLESHOOTING
ERROR CODES
When the washer senses an error all machine operations will stop, a series of 4
beeps will sound and an error code will be shown in the Estimated Time Remaining
display.
ERROR CODE
dO
The washer has detected
that the lid is open.
(Washer Lid is Open)
The washer has detected
Ld
that it is taking too long
(Too Long to Drain
to completely drain water
Water)
from the wash tub.
The washer has detected
UL
an out of balance load and
has failed to self correct
(Unbalanced Load)
the condition.
The washer senses that it
is taking too long to ll the
LF
wash tub or does not read
(Too Long to Fill)
a change in water level
during a ll.
FA
The washer has detected
(Water Level Sensor
water level sensor errors.
Error)
The washer has detected
F2
higher than normal water
(Water Level is Too
levels, automatic draining
High)
has not resolved the issue.
The washer senses that
E5
Hot water is too cold, or
(Water Temperature
Warm, Cool, Cold, and Tap
Problem)
Cold water is too hot.
WASHER DOES NOT OPERATE
•
Check that the power cord is plugged into a grounded 3 prong outlet.
•
Check that the electrical wall receptacle is of proper voltage.
•
Check if the circuit breaker needs to be reset or if the fuse needs to be replaced.
DESCRIPTION
POSSIBLE CAUSE AND SOLUTION
The washer will not start with the
washer lid open. If the lid is opened
during the wash cycle, it may
continue to run. However, when it
reaches a stage that requires the
lid to be closed, the error will occur.
Closing the lid should dismiss
the error and resume normal
operation.
Check to make sure the drain hose
is properly installed. The open end
of the drain hose should not be
submerged in water.
Open the washer lid, redistribute
the load, close the lid, and the
washer will resume operation.
Check to make sure that the
water hoses are connected to the
washer, there are no kinks in the
hoses, and that the supply valves
are fully opened.
Call for Service.
Call for Service.
Check to make sure that your
hot water heater is supplying hot
water. Check to make sure that
the water hoses are connected to
the proper valve; hot to hot, cold
to cold.
21