Descargar Imprimir esta página

GE Profile WPDH8850 Manual Del Propietario E Instalación página 16

Ocultar thumbs Ver también para Profile WPDH8850:

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION OF YOUR WASHER
Do Not Install the Washer:
1. In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (15.6°C) for proper
washer operation.
2. In an area where it will come in contact with curtains
or drapes.
3. On carpet. The floor MUST be a hard surface with
a maximum slope of 1/2" per foot (1.27 cm per
30 cm). To make sure the washer does not vibrate
or move, you may have to reinforce the floor.
NOTE: If floor is in poor condition, use 3/4" impregnated
plywood sheet solidly attached to existing floor covering.
IMPORTANT:
Minimum Installation Clearances
• When installed in alcove: Sides, Rear,
Top = 0" (0 cm)
• When installed in closet: Sides, Rear,
Top = 0" (0 cm), Front = 1" (2.54 cm)
• Closet door ventilation openings required:
2 louvers each 60 square in. (387 cm
(7.6 cm) from top and bottom of door
Installation Instructions
), located 3"
2
16
ROUGH-IN DIMENSIONS
FRONT
27.0"
(68.6 cm)
32.1"
(81.5 cm)
*NOTE:
With Washer Legs: 40.5" (102.5 cm)
(0.75" adjustability)
With Pedestal: 53.75" (136.6 cm)
(0.75" adjustability)
Stacked: 82.75" (209.8 cm)
39.2"*
(99.5 cm)
SIDE
39.2"*
(99.5 cm)

Publicidad

loading

Este manual también es adecuado para:

Profile wpdh8900