ENG
PELLET FIREPLACE
(Rev. 15/10/2013)
The pellet fireplace is shipped with all components on the left side: the only time you have to do is move the beam
(A) at the rear of the holes below the upper holes to allow the fitting of flue pipe. The traverse is shipped in the lower
position for transportation needs and convenience when traveling.
If you want the fireplace with the right components, you have to do when ordering (option at extra cost).
It 's strictly prohibited the movement of electrical components later, or lose the
warranty. It 'a task that must be done only in the factory by the productor.
If you want to reverse the side of the pellet load, unscrew the front and rear of the tank, remove the upper cover and
the charger and put them back in the new location.
IMPORTANT: On the side of the electrical components in the coating must include a cover technical inspection
for routine maintenance with opening large enough to access the components (minimum size L 50 x H 120 cm).
For a correct recirculation of hot air, we recommend connecting the collar B (opposite to the centrifugal fan) to a tube
and a outlet diameter of 80 mm outside the plasterboard lining.
We recommend to isolate the hood inner with panels Firerock (rock wool insulation panels of 30 mm coupled to an
aluminum foil, aluminum side toward the insert) observing a minimum distance of 3 cm by the insert.
8. THE SMOKESTACK
The smokestack must always satisfy the UNI 10683 regulation in force in Italy at the time being. Each stove shall be
only connected to a single chimney. The chimney ahs to be build in proper way to allow cleaning and inspection. All
chimneys and connection piping must be identify by an approved tag showing all typical data as per the UNI 10682
Italian regulation. For all other countries, accordance with local and national regulations in force.
Smoke evacuation system components designation example:
Temperature class (es: T400 minimum, T450-T600 suggested)
The smokestack temperature class (as per UNI EN 1443) should not be lower than the maximum exhaust gasses
temperature declared by the stove manufacturer.
For all appliances as per UNI EN 14785 (appliances for home heating burning wooden pellet as fuel – requirements
and testing procedure) temperature class lower than T400 are not allowed. In any case always check the stove data