BIP A/CD2-T017-01-EB/EP _ _ (-S4/S49)
Inductive Position System
Installation and connection
Installation instructions
In order to prevent interference with the measurement
signal, a metal-free area of approximately 5 mm should be
maintained around the entire active area of the BIP (see
figure). If the BIP detects not only the target, but also
another metal piece, invalid measurement signals will
result.
To obtain a measurement signal with high resolution,
suitable cable routing in the machine and filter measures
for system power supply must be ensured.
Active surface
25.5
The target can be moved in the range D = 0.5...1.25 mm
in front of the active surface in the direction of
measurement (see figure). The resulting linearity error of the
output signal is minimal in the distance range
D = 1.0 ±0.25 mm.
www.balluff.com
Installation
► Fasten BIP with 2 mounting screws DIN EN ISO 4762
M4 x 14 (max. tightening torque: 0.5 Nm).
Shielding
To ensure electromagnetic compatibility (EMC), the cable
shielding must be grounded on the controller side
(connected with the protective earth conductor).
≥5
8
Cable routing
Do not route the cable between the BIP, controller, and
power supply near high voltage cables (inductive stray
noise is possible).
Inductive stray noise from AC harmonics (e.g. from phase
angle controls) are especially critical and the cable shield
offers very little protection against this.
Electrical connection
20
3
4
S4 connector
Pin (S4/S49)
1
3
4
Target BAM TG-XE-020
17.5
(2)
1
3
1
4
S49 connector
Wire color
Brown
Blue
Black
english
Signal
+
Output
2