Troubleshooting Procedures (cont.)
Symptoms
5.
Hot water in cold supply or
cold water in hot supply.
6.
Maximum blend temperature
setting too hot or too cold.
7.
Water leaking from the valve
body.
8.
Flow knob or temperature
knob is stiff to operate.
Warranty
FIVE-YEAR LIMITED WARRANTY
All Kallista products carry Kallista's five-year limited warranty unless
otherwise noted.*
Kallista products are warranted to be free of defects in material and
workmanship for five years from the date of installation.
Kallista will, at its election, repair, replace, or make appropriate
adjustment where Kallista inspection discloses any such defects
occurring in normal usage within five (5) years after installation.
Kallista is not responsible for removal or installation costs. Use of
in-tank toilet cleaners will void the warranty.
To obtain warranty service, contact your Kallista Authorized
Showroom.
Implied warranties including that of merchantability and fitness for
Kallista
Probable Cause/Recommended
Action
C. Hot supply temperature
fluctuation.
D. Supply pressure fluctuation.
A. Indicates crossflow. Replace
check valve.
A. Indicates incorrect maximum
temperature setting; refer to the
"Adjust the Hot Temperature
Limit" section.
B. Refer to symptom 4.
C. Refer to symptom 5.
A. Seal(s) worn or damaged.
Obtain service kit and replace
seal(s).
B. If leaking from around the
temperature spindle, replace the
thermostatic cartridge.
A. Impaired free movement of
internal components. Replace the
appropriate cartridge.
B. Supply pressures are too high.
Fit pressure reducing valve.