B5.
ADAPTING BLOWER FOR
OUTSIDE BACK EXHAUST
1 Remove the two screws that hold the blower plate
and remove the screw holding the blower motor
to the oven. Slide blower plate from under its
retaining flange.
Retaining
Flange
2
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
BEFORE: Fan Blade
Openings Facing Up
3 Rotate blower unit counterclockwise 180°.
Before Rotation
Back of
Oven
Roll the blower unit 90° so that fan blade
4
openings are facing out the back of the
oven.
Before Rolling
Back of
Oven
All manuals and user guides at all-guides.com
Installation Instructions
Blower Plate
Back of
Oven
After Rotation
Back of
Oven
After Rolling
Back of
Oven
Locate the two "knockout" plates, on the rear
5
oven panel, near the top of the oven.
Using tin snips, carefully cut the web area from
the two holes side-by-side (that secure the
knockouts to the oven). Cut all four webs on
both rear knockouts; this will allow the
ventilation fan airflow to exhaust out the
rear of the oven.
CAUTION: Be sure to trim the sharp edges from
the openings after removing the knockout plates.
Oven Rear Panel
6
Place the blower unit back into the opening.
AFTER: Fan
Blade Openings
Facing Back
CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
7
Replace the blower plate in the same position
as before and replace the screws for the
blower plate and blower motor.
Blower Plate Screws
17
Snip all 4 webs
on each knockout
panel and remove
the metal knockouts
for rear airflow.
Blower Plate
Back of Oven
Blower Motor Screw