Water flow rate insufficient
1) Suction lift and/or head excessive. 1) Excessive suction lift and head and external components all
reduce the flow rate! This is not a malfunction.
2) Foot valve suction strainer obstructed. 2) Clean the suction strainer.
3) Water level in suction point drops too fast. 3) Immerse the foot valve in a greater depth of water.
4) The appliance's flow rate is being reduced by soil in the water.
4) Clean the pump body (A4) by directing a jet of water in through
the suction fitting (A1) and delivery fitting (A2), and if necessary
have the appliance checked by the Service Centre. Use a pre-filter
if the appliance does not have an integral pre-filter (A1 b).
The thermostat is cutting out the
appliance
1) Motor overloaded due to friction between dirt particles and
impeller.
Dry operation or flow of water insufficient.
1) Clean the inside of the pump body (A4) by directing a jet of water
in through the delivery fitting (A2), leave the thermostat to cool for
about 1 h, and if necessary have the appliance checked by the
Service Centre.
2) Dry operation.
2) Check that there is water present, leave the thermostat to cool
for about 1 h, and if necessary have the appliance checked by the
Service Centre.
(*) If the motor stops and does not restart during operation contact the Service Centre.
12
ENGLISH (Original instructions)
EN
Technical Data Unit BXGP600PE BXGP800XE BXGP1100XE
Voltage V/Hz 230 V ~ 50 Hz 230 V ~ 50 Hz 230 V ~ 50 Hz
Power W 600 800 1100
Max. head (Hmax) m 35 38 45
Max. flow rate (Qmax) l/h 3100 3500 4600
Max. water temperature (Tmax) °C 35 35 35
Max. suction lift m 8 8 8
Max. particle size Ø mm 0 0 0
Protection class -
Motor insulation - Class B Class B Class B
Motor protection - IPX4 IPX4 IPX4
Sound power level LWA (EN ISO 3744) dB (A) 76 79 84
Net weight kg 6.3 6.5 9.1