OPTIONS SELECTOR 1
OPTION 1 - Automatic closing
ON
Door closes automatically after waiting the a.c.time
OFF
Door does not close automatically
OPTIONS SELECTOR 2
OPTION 1 - Disable stop on opening
ON
Opening the alternative button is disabled
OFF
If alternative button is pressed door stops
OPTION 2 - Electro lock
ON
Door closes 1 sec. Before closing
OFF
Door opens normally
OPTION 3 - Soft Stop
ON
Motor makes soft stop at the end of manouvre.
OFF
Without soft stop.
OPTION 4 - Close by safety contact
ON
Door will close if open when photocell is deactivated
OFF
Normal photocell working conditions
OPTION 5 - Photocell 2 / safety edge
ON
Input 17-18 (BAND) configured as resistive 8K2.
OFF
Input
17-18 (BAND) configured as mechanical N.C.
OPTION 6 - Pressure switch / Pedestrian
ON
Terminals 20-21 are configured as N.C and works as a security
pressure switch. Is disabled on opening and inverts the action on
closing.
OFF
Terminals 20-21 are configured as N.O ans works as a pedestrian
switch. Opens the door for 7 seconds.
OPTION 7 - Hourly impulse
ON
If the door is open and not in use(dormant) the control pannel
opens the door for 6 sec every hour. If the door is closes then the
control pannel closes the door for 6 secons on the hour
OFF
Normal working conditions
OPTION 8 - Digital Timing
ON
Digital times are memorized through programming button
Instruction Manual
(QRF GR HIDRÁULICO)
DIGITAL PROGRAMMING
of open, close and automatic close.
Before programming disconnect the control panel and:
All connections are connected correctly.
All option selections are in OFF except I8 which should be switched ON.
The door is completely closed.
Once the above is revised, connect the control panel and begin to program the opening times. The door must have been automatically
closed.
1- Press the programming button until the programming led comes on. The led will flash while the times are being
2- Enable the start button using the transmitter or the test button. The door will begin to open.
3- Once the required opening point is reached, stop the door by pressing the start button or wait for it to stop automatically if the
opening limit switch is connected.
4- The standby time for automatic close will then begin to be counted. After the required time, press the start button again and the door
will begin to close.
5- Once the door has closed, press the start button again or wait for the door to stop automatically if you have the closing limit switch
connected. The programming led will switch off and programming will be complete.
OPERATING INSTRUCTIONS
The door operates via the alternative button ( TEST / CI, P.ALT terminals, or by the radio card).
Door operation finishes by the following: by the corresponding limit switch(FC) of by finalizing the working time.
If an order is given during opening the door will stop & the door will not close automatically.
If an order is given during closing the door will open.
Activation of C.SEG during closing the door will open.
The garage light comes on once the door begins to open and turns off 2 sec. after closing.
The public door button (20-21 N,O) opens for 16 sec. if activated.
NOTES
Pressure switch active only on closing. For activate it on opening, turn off the power supply, push the prog. time button and keep it
pressed during 7 seconds when the power supply is turned on again.
programmed