GB
TECHNICAL SPECIFICATIONS
Power
220V AC +/- 10%
Max Drive Power
0.75HP
Power Suply for accessories
12V AC 200mA
Garage door output type
Power free contact
Electric lock
12V 1A.
Opening Time
From 3 sec to 40 sec (40 to 80 sec)
Closing Time
From 3 sec to 40 sec (40 to 80 sec)
Automatic closing time
From 5 sec to 110 sec
Temperature
0 to 70º
Housing dimensions
170x140 mm
WARNING!!
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT
MUST BE INSTALLED FOR SYSTEMS THAT ARE ALWAYS
CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE
IS SWITCHED OFF.
Instruction Manual
(QRF GR HIDRÁULICO)
STANDARD CONTROL PANEL SET UP
1 2
POWER
SUPPLY
TERMINALS
220V
TIME REGULATIONS
AUTOMATIC CLOSING TIME (RED)
Regulates the waiting time before the automatic close
Turn LEFT to decrease and
-
+
Minimum - 5 sec
Maximum - 90 secs
CLOSING TIME (GREEN)
Regulates the closing time
Turn LEFT to decrease and
-
+
Minimum - 3 sec ( 10 sec if DIP I3 is ON)
Maximum - 60 secs (80 sec if DIP I3 is ON)
BRIDGE SELECTORS
PHOTOCELL / RESISTIVE SAFETY EDGE
PHOTOCELL - Normally closed (e.g photocell)..
RESISTIVE SAFETY EDGE - Normally closed
contact . 8K2 safety edge
ACCESSORIES
GARAGE
POWER
LIMIT
LIGHT
SUPPLY
SWITCHS
13 14 15
11 12
6 7
10 18
GARAGE
CLOSE OPEN
LIGHT
12V
12V
LIMIT SWITCHES
3
4 5
SINGLE PHASE
DRIVE
M
DRIVE
OPENING TIME (WHITE)
RIGHT
to increase
-
+
PRESSURE SWITCH TIME (BLUE)
RIGHT
to increase
-
+
TRAFFIC LIGHT / FLASHING LIGHT
TRAFFIC LIGHT - Green light is ON during automatic closing
time. Before closing, the light will flash for 4 secs. The red light
is ON during opening and closing.
FLASHING LIGHT - During the opening, flash relay output, is
activated as fixed light. During the closing, it works intermittently
(flash).
SAFETY EDGE
BUTTONS
SAFETY
(OPTION 5 ON)
17
18 19
20 21 22
17 18
8K2 Ohm
N.O
PEDEST.
ALT.
Safety Edge
SAFETY
BUTTON
BUTTON
SWITCHES
20 21 22
PUSH
BUTTONS
TERMINALS
PEDEST.
ALT.
BUTTON
BUTTON
Regulates the opening time
Turn LEFT to decrease and
RIGHT
to increase
Minimum - 3 sec ( 10 sec if DIP I3 is ON)
Maximum - 60 secs (80 sec if DIP I3 is ON)
Regulates the time of pressure switch.
Turn LEFT to decrease and
RIGHT
to increase
ELECTRIC
PHOTOCELL
TEST
LOCK
17 18
16
0v
N.C
PHOTOCELL
TEST
Safety Edge
8 9
ELECTRIC
ELECTRIC
LOCK
LOCK
Page 2 - 2