The junction box should be
wired as shown.
Line (Black)
Electrician to
provide suitable
strain relief.
Supply
Neutral (White)
9. Make the Electrical Connections – Canada
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the blower motor to a properly grounded,
grounding-type Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard.
Locate and secure each supplied junction box a minimum of 1-1/2" (38 mm) above the subfloor.
The bath controls and system have been prewired at the factory. A qualified electrician should make
a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A GFCI or RCD.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
1220597-2-C
Bond in accordance with
national and local codes.
Ground (Green with Yellow Stripe)
Wire Connectors
From Blower Motor
From Blower Motor
Black
L1
N
White
Green with Yellow Stripe
GND
12
Blower Motor
Electrical Cord
Kohler Co.