• If a piston is not used with the barrel, an inline filter (881-000-000), not
included, and must be installed on the receiver head to help prevent fluids from
being sucked back into the unit. Also do not overfill the barrel and to lay the
barrel on its side
• Do not smoke or use open flame when flammable materials are being dispensed
• This equipment is for indoor use only
2
SYMBOL DEFINITIONS
Symbol
Definition
Power On/Off
Cycle Mode
Timer
Vacuum
Pressure
3
SPECIFICATIONS
152mm X 165mm X 178mm
Size
(6" X 6.5" X 7.0")
Weight
1.2 kg (2.6lbs)
Input Voltage
24VDC
Rated Power
10W
Air Input
100 psi (6.9 bars) Max.
Pollution Degree
II
Installation Category
I
Indoor Use
Altitude up to 2,000m (6,562ft)
Operating Temperature
0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature
-10˚C to 60˚C (14˚F to 140˚F)
80% for temperature up to 31˚C (87.8˚F) Decreasing
Max. Relative Humidity
linearly to 50% relative humility at 40˚C (104˚F)
Air Output
0-100 psi (0-6.9 bars)
Vacuum
406mm (16") of Hg
Timer
0.020-99.999 seconds
Cycle Mode
Manual, Timed
Timing Repeat Tolerance
+/- 0.001%
Cycle Rate
600 cycles/min
LCD
16 X 2 display segments
All manuals and user guides at all-guides.com
3
4
FEATURES
3
4
2
1
5
6
8
7
Figure 1.0
Items
Description
Power Button
1
Mode Button
2
Set up/Save Button
3
Display
4
Air Pressure Gauge
5
Air Pressure Regulator
6
Pulsed Air Outlet
7
Vacuum Control
8
Receiver head air hose holder
9
Foot Switch Receptacle
10
Power Receptacle
11
I/O Connection
12
Accessory Air Outlet
13
Exhaust Port
14
Air Inlet
15
Cord Lock
16
9
11
10
16
15
4
12
14