Descargar Imprimir esta página

IP Cleaning HTM D2015P Manual De Instrucciones página 26

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
USE OF THE DOUBLE LAN-
CE. (fig.11) (if available).
The double lance allows the
operator to select a low or high
pressure jet. The pressure is
selected with the gun in pos.
1. High pressure: pos. 2. Low
pressure.
REGULATING PRESSURE
AND USING STEAM.
This chapter concerns only
those models provided with
the "pressure regulating" de-
vice. The pressure regulator,
fig. 12, allows the operator to
adjust the working pressure.
When knob C is turned in
an anti-clockwise direction
(B) (minimum), the working
pressure is reduced.
USING H Mode.
Turn the thermostat knob "B" (fig. 7) to H Mode position to
obtain an increase in the temperature of the water at delivery.
!
Danger
During use with boiling water, "H Mode Phase", keep away
from the openings for fumes discharge (risk of burning).
When you have finished using the "H Mode Phase", turn the
thermostat knob "B" to position "0" (fig. 7) and let the ma-
chine cool down for about 3 minutes with the gun turned on.
ADVICE ON USING DETERGENTS
!
Warning
This appliance has been designed for use with the detergents
and/or chemicals supplied or recommended by the manufac-
turer. The use of other detergents or chemicals may influence
the safety of the cleaner.
1)
For environmental
compatibility, we recommend a reaso-
nable use of detergents, according to the instructions on the
pack.
2) From the range of recommended products, choose the
one most suited to the washing job to be done and dilute it
with water according to the instructions on the pack or in the
catalogue of the detergents most suited for the type of hot or
cold water cleaner.
3) Ask your dealer for the detergents catalogue.
English
OPERATING PHASES FOR CORRECT CLEANING WITH
DETERGENTS.
1) Prepare the solution of detergent at the concentration
most suitable for the type of dirt and the surface that is to be
washed.
2) Start the cleaner, turn on the detergent tap, and spray the dirty
surface with the diluted product, working from bottom to top.
Let it react for a few minutes.
The temperature selector must be in the hot water washing
position (< 60°C).
3) Rinse the whole surface well from top to bottom with hot or
FIG. 11
cold water at high pressure.
4) Disinfect the surface by spraying it with hot water > 90°C after
having placed the temperature selector in the H Mode position.
(Yellow
indicator light on
!
Warning
Using very hot water may affect the efficiency of rubber parts
(tyres, gaskets, etc.).
5)
After use with detergent, rinse the high pressure water circuit
by operating the pump for one minute with the detergent tap
completely closed.
FIG. 12
ONLY THE OPERATIONS AUTHORIZED IN THIS IN-
STRUCTIONS MANUAL MAY BE CARRIED OUT BY THE
ALL OTHER OPERATIONS ARE FORBIDDEN.
!
Danger
For maintenance of the boiler, high pressure pump, the electrical
parts and all parts with a safety function, you must apply to our
Technical service centre.
The manufacturer is not liable in case of tampering, changes, in-
correct repairs or maintenance carried out on the machine by a
third person not provided with the manufacturer's authorization.
All documents pertaining to the repair and planned service
interventions, as well as any certificates concerning the device
installation according to the laws in force (in compliance with the
provisions of the IEC 60364-1 standard) must be kept carefully
by the user, together with the Instructions Manual.
Periodically, at least once a year, have the safety devices and
the rated values checked at one of our technical service centres.
Particularly, as for the hot water high pressure cleaner, which is
factory set, the exhaust system must be checked.
The rating done by the manufacturer determines a production of
exhaust gases with a CO content lower than 0,04% and a smoke
content corresponding to a smoke point nr.2 Shell-Bacharach
according to the laws in force.
!
Danger
Disconnect the water cleaner from the mains electricity supply
via the omnipolar switch or by unplugging the plug from the
- 26 -
steady).
MAINTENANCE
USER.