5 – TECHNICAL DATA
PRIMARY
Single phased power supply
Frequency
Maximum primary current (MMA)
Maximum primary current (TIG)
Maximum power consumption (MMA)
Maximum power consumption (TIG)
SECONDARY
No-load voltage
Welding current range
Welding current at 40 %
Welding current at 60 %
Welding current at 100%
Protection degree
Insulation class
Norms
Weight
Dimensions
6. INSTALLATION
6.1 CONNECTION TO THE MAIN SUPPLY
This unit must be connected to a mono-phase 230V - 50 Hz/60 Hz + ground.
Main supply must be protected by fuses or circuit breaker according to the value I1eff written on the
specifications of the power source.
It is strongly suggested to use a differential protection for the operator's safety.
6.2 CONNECTION TO EARTH
For the operator's protection, the power source must be correctly grounded (according to the International
Protection Norms).
It is necessary to set a good earth connection with the green/yellow wire of the power cable. This will avoid
discharges caused by accidental contacts with grounded pieces. If no earth connection has been set, a high
risk of electric shock through the chassis of the unit remains possible.
MICRO DC 162
V
1 x 230 V (-+10%)
Hz
50/60
A
34
A
24
KVA
7,8
KVA
5,5
V
74
A
10 - 160
A
160
A
135
A
105
IP 21S
H
IEC / EN 60974-1
Kg
5,1
cm
15 x 24 x 32
MICRO DC 162/202
MICRO DC 202
1 x 230 V (-+10%)
50/60
43
30
9,9
6,9
80
10 - 200
200
160
125
IP 21S
H
IEC / EN 60974-1
5,7
15 x 24 x 32
10