Start Using Your Cooker Hood
Rocker switch
1. Insert the power plug into the socket.
2. Push switch 1 to " ", the lamp will be on; push switch
1 to "0" the lamp will be off
3. Push switch 2 into "I, II" , the motor will be on; "low or high"
two speeds, push into "0", the motor will be off.
4. The power will be connected when pull out the front panel.
Conversely, the power will be automatically disconnected.
Fault
Light on, but motor does not work
Light does not work, motor does not
work
Oil leakage
Lights not working
Insufficient suction
The Cooker hood inclines
NOTE:
Any electrical repairs to this appliance must conform to your local, state and federal laws.Please contact
the service centre if in any doubt before undertaking any of the above.Always disconnect the unit from
the power source when opening the unit.
OPERATION FOR VDE6065SR
TROUBLESHOOTING
Possible Cause
Fan switch turned off.
Fan switch failed.
Motor failed.
House fuses blown.
Power cord loose or disconnected.
One way valve and the outlet are not
tightly sealed.
Leakage from the connection of
chimney and cover.
Broken/Faulty globes
The distance between the cooker
hood and the gas top is too far
The fixing screw not tight enough
[ EN ● 12 ]
KEN002DH 24.02.2021
Solution
Select a fan switch position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Take down the one way valve and seal
with sealant.
Take chimney down and seal.
Replace globes as per this instuction
Refit the cooker hood to the correct
distance.
Tighten the hanging screw and make
it horizontal.
Version: 3:0