24 INSTALLATION
Connecting the Gas Supply
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier. Failure to do so may result in fire,
explosion, or death.
• Use only a new stainless steel flexible
connector and a new AGA-certified connector.
Failure to do so may result in fire, explosion, or
death.
• A gas shutoff valve must be installed within 6 ft.
(1.8 m) of the dryer. Failure to do so may result in
fire, explosion, or death.
• The dryer is configured for natural gas when
shipped from the factory. Make sure that the
dryer is equipped with the correct burner nozzle
for the type of gas being used (natural gas or
propane gas). Failure to do so may result in fire,
explosion, or death.
• If necessary, the correct nozzle (for the LP
nozzle kit, order part number 383EEL3002D)
should be installed by a qualified technician
and the change should be noted on the dryer.
Failure to do so may result in fire, explosion, or
death.
• All connections must be in accordance with
local codes and regulations. Failure to do so may
result in fire, explosion, or death.
• Gas dryers MUST exhaust to the outdoors.
Failure to do so may result in fire, explosion, or
death.
NOTE
This dryer is configured from the factory for
natural gas (NG). If the dryer is to be used with
propane (LP) gas, it must be converted by a
qualified service technician.
1
Make sure that the gas supply to the laundry
room is turned OFF and the dryer is unplugged.
Confirm that the type of gas available in your
laundry room is appropriate for the dryer.
2
Remove the shipping cap from the gas fitting at
the back of the dryer. Be careful not to damage
the threads of the gas connector when removing
the shipping cap.
3
Connect the dryer to your laundry room's gas
supply using a new flexible stainless steel
connector with a 3/8-inch NPT fitting.
NOTE
DO NOT use old connectors.
4
Securely tighten all connections between the
dryer and your laundry room's gas supply.
5
Turn on your laundry room's gas supply.
6
Check all pipe connections (both internal and
external) for gas leaks with a noncorrosive leak-
detection fluid.
7
Proceed to Venting the Dryer.
3/8"
NPT gas
Connection
AGA/CSA-Certified
Stainless Steel
Flexible Connector
High-Altitude Installations
The BTU rating of this dryer is AGA-certified for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation
above 10,000 feet, it must be derated by a qualified
technician or gas supplier.
1/8" NPT Pipe Plug
Gas Supply Shutoff
Valve