Descargar Imprimir esta página

GE JGP985 Manual Del Propietario E Instrucciones De Instalación página 25

Estufa de cubierta a gas con tiro descendente

Publicidad

Idiomas disponibles

Idiomas disponibles

Calculate Total Equivalent Ductwork Length
Equivalent
Duct Pieces
Length* x
6" round
straight
1 ft.
" x 10"
3
1
4
straight
1 ft.
6", 90°
elbow
15 ft.
6", 45°
elbow
9 ft.
24" max.
Flexible
Metal Offset
Adapter
34 ft.
" x 10"
3
1
4
90° elbow
16 ft.
" x 10"
3
1
4
45° elbow
5 ft.
" x 10"
3
1
4
90° flat elbow 18 ft.
6" round
" x 10"
to 3
1
4
transition
7 ft.
Subtotal Column 1 =
*Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good venting
performance with any downdraft cooktop.
† Measure and list feet of straight duct used. Count
and list the quantity of all other duct pieces for the
"Number Used" of each type.
IMPORTANT
For maximum efficiency, use the shortest and
straightest duct run possible, with as few fittings as
possible. For satisfactory performance, the duct run
should not exceed 100 feet equivalent length.
Venting performance is improved by using larger
diameter duct.
Installation Instructions
DUCTWORK CALCULATIONS
Number
Equivalent
Used =
Length
x
(
)
=
ft.
x
(
)
=
ft.
x
(
) =
ft.
x
(
) =
ft.
x
(
) =
ft.
x
(
) =
ft.
x
(
) =
ft.
x
(
) =
ft.
x
(
) =
ft.
ft.
Duct Pieces
6" round
" x 10"
to 3
1
4
transition
90° elbow
" x 10"
3
1
4
to 6" round
transition
" x 10"
3
1
4
to 6" round
transition
90° elbow
6" round
wall cap
with damper 21 ft.
" x 10"
3
1
4
wall cap
with damper 27 ft.
6" round
roof cap
6" round
roof vent
DO NOT use flexible plastic ducting.
Vent installation should not exceed 100 feet
equivalent length.
25
Equivalent
Number
Equivalent
Length* x
Used =
Length
20 ft.
x
(
) =
5 ft.
x
(
) =
12 ft.
x
(
) =
x
(
) =
x
(
) =
20 ft.
x
(
) =
24 ft.
x
(
) =
Subtotal Column 2 =
Subtotal Column 1 =
TOTAL DUCTWORK =
Should not exceed 100 feet.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.

Publicidad

loading