INFO FUNCTION
By pressing
(INFO) button, temperature around remote controller and monthly power consumption will
●
be displayed on the remote controller.
After changing the batteries, direct the remote controller towards the indoor unit and press
●
Current calendar and clock will be transmitted from indoor unit.
In order to receive information from indoor unit, the distance between remote controller and receiver of indoor
●
units is within 2 meters.
NOTE
In case failure occurs to the air conditioner, by pressing
●
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit)
and press
(INFO) button. Wait for 2 seconds for signal transmission.
An error code will be displayed.
Call service center and inform the error code.
Info Function to check monthly power consumption.
●
During installation, in case of power failure or breaker ON / OFF, ensure to set the clock and calendar for each
indoor unit (unit in standby mode or auto restart), for single or multi connection, by pressing
button.
Failure to do the above,monthly power consumption amount will not be displayed on the remote controller.
All manuals and user guides at all-guides.com
■ To check temperature around remote controller
Press
(INFO) button.
1
Temperature will be displayed for 10 seconds.
■ To check monthly power consumption
Direct the remote controller towards the receiver of indoor unit (within 2
meters in front of indoor unit) and press
seconds for signal transmission.
While temperature around remote controller is displayed, press
button repeatedly. The display will show as below:
this month power consumption amount for heating
amount for heating
this month power consumption amount for cooling
month power consumption amount for cooling
controller
this month power consumption amount for heating ...... cyclically.
If indication is not given, bring remote controller closer to the receiver of
●
the indoor unit.
Indicated value shall be regarded as a guide only.
●
■ Current calendar and clock can be retrieved from indoor unit
Direct the remote controller towards the receiver of indoor unit (within 2
meters in front of indoor unit) and press
seconds for signal transmission.
Once received the current calendar and clock, check whether they are correct
or not by pressing
If there is no power supply to indoor unit or calendar and clock have not been
●
set, INFO function cannot be used for sending or receiving information.
– 26 –
(INFO) button. Wait for 2
last month power consumption
temperature around remote
(INFO) button. Wait for 2
(CLOCK) button.
(INFO) button, an error code will be displayed.
(INFO) button.
(INFO)
last