To get an estimate of the current (in Amps) that the battery is delivering, divide the
load's AC consumption power (in Watts) by (10).
Keep in mind that most appliances are not operating for long periods of time. for
example, a typical home use coffee maker draws 500 Watts during its brew time
of 5 minutes, but it maintains the temperature of the pot at about 100 Watts.
Typical use of a microwave is only for a few minutes, sometimes at low power.
Some exceptions to brief operating times are TVs, computers etc.
In most instances, the inverter can be left connected to the battery when not in use,
make sure power switch is in the OFF position.
Battery performance drops in low temperature environment. Higher capacity
batteries should be installed if the environmental temperature is below 20℃.
PROTECTIVE FEATURES OF THE INVERTER
OVER TEMPERATURE PROTECTION
The unit is cooled by temperature controlled fan(s). The fan(s) will run at full speed
when the interior inverter temperature goes over 50℃. In case the fan fails or if the
cooling is inadequate due to higher ambient temperature or restricted air flow, the
temperature inside the inverter will be too high and the unit will automatically shut
down. Allow the unit to cool for at least 15 minutes before restarting after a heat-
related shutdown. Unplug unit while cooling.
LOW BATTERY VOLTAGE PROTECTION
This condition is not harmful to the inverter but could damage the power source.
The inverter automatically shuts down when input voltage drops to 10 Volts.
(For 12V DC Input )
OVER VOLTAGE PROTECTION
The inverter will automatically shut down when the input voltage exceeds 15 Volts
DC.Input voltage exceeding 16 Volts could damage the inverter.(For 12V DC Input)
OVERLOAD PROTECTION
The inverter will automatically shut down when the continuous draw exceeds rated Watts.
SHORT CIRCUIT PROTECTION
The inverter will shut down. Remove the short circuit and restart inverter.
EARTH FAULT PROTECTION
This inverter complies with the standard current leakage allowance. When large
current leakage to earth terminal occurs, the protection circuit activates and shuts
down the inverter,which prevents electric shock to humans. Turn OFF the inverter,
unplug the fault AC appliance and then turn ON is the only way to restart it.