b. Put the switch in the ¨OFF¨ position.
c. Close the fuel tap when finishing use (OFF).
6.5. CHECKING POINTS AFTER START UP
Check that there is no air in the aspiration hose.
Check that all the racors are correctly tightened and
that there are no water leakages on the main body of
the pump, through the racors or in the impulsion hose.
por la bomba, los racores y la manguera de impulsión.
6.6. END OF USAGE
After using the machine, empty the water that is
inside the machine. To do this, unscrew the emptying
water screw and wait for the water to empty from the
machine. After this, screw back into place.
7. MAINTENANCE AND SERVICE
The objective of the maintenance and service is to
ensure that your machine works always in the best
possible conditions both in efficiency and security.
Follow the recommendations and the maintenance
periods included in this manual.
Turn off the engine before doing any adjustments,
change of accessories or storing the machine.
Action
Check
level
Engine
oil
Change
Check
Air filter
Change
Spark
Check/
plug
adjust
Deposit
Clean
filter
7.2. OIL CHANGE
To do the oil change, the oil must be hot to guarantee
that oil filters out correctly and quickly. If you are
going to change the oil, do so after using the machine
if not you will have to start the machine for a few
minutes prior to changing the oil so as to heat the oil.
Remember that the machine should not be started
with the pump empty (the pump must be filled up with
water).
Oil change:
1. Stop the machine.
2. Place the machine in a horizontal position
and in such a way that the oil drains
out into a recipient. Remember that this machine
has a capacity for 0.37 l and therefore the
recipient must have at least this volume.
3. Remove the oil cap.