Descargar Imprimir esta página

T.I.P. HWA 4500 INOX Instrucciones Para El Manejo página 13

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
The device is not suited for use in swimming pools.
The automatic booster sets from T.I.P. were developed for private use, i.e. not for industrial purposes or for
uninterrupted recirculation operation.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. and min. temperatures of the liquids to be
discharged stated in the technical data.
3.
Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Suction port
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. suction height
Max. size of the solids being pumped
Max. permissible operating pressure
Min. ambient temperature
Max. ambient temperature
Min. fluid temperature
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Guaranteed sound power level (L
Measured sound power level (L
2)
Sound pressure level (L
)
pA
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to
EN ISO 3744.
4.
Scope of delivery
The scope of the delivery of this product includes:
One pump with a connection cord, one electronic pump control system, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.
Assembly of the automatic booster set
Please observe also at the illustration given in Fig. 1 which is found as an attachment at the end of the present
operating instructions. It contains the numerical and other details which are set between brackets in the
specification below.
The automatic booster set consists of a self-priming electrical pump (17) and an electronic pump control system
(18) which can be assembled within seconds through a simple threaded connection.
HWA 3000 INOX
230 V ~ 50 Hz
550 Watt
IP X4
30.93 mm
33.25 mm
2,800 l/h
4.2 bar
42 m
9 m
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H07RN-F
~ 6.7 kg
2)
80 dB
)
WA
2)
77,4 dB
)
WA
69,4 dB
35.5 x 18 x 42 cm
31142
, female
(1 ")
, male
(1 ")
2
HWA 4500 INOX
230 V ~ 50 Hz
1,200 Watt
IP 44
30.93 mm
(1 "), female
33.25 mm
(1 "), male
4,350 l/h
5.0 bar
50 m
9 m
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H07RN-F
~ 10.0 kg
86 dB
84.1 dB
78.5 dB
37 x 21 x 55 cm
31193
10

Publicidad

loading

Este manual también es adecuado para:

Hwa 3000 inox