1.1. ESTADO DE SUMINISTRO
REL
TEST
M
Ω
OFF
V
50V
Ω
100V
Ω
k
MR -
C.A 6532
MEGOHMMETER
English
Safety data sheet Measuring Instrument in CAT II or CAT III or CAT IV
(en)
For your safety and to avoid damage to property:
Read what follows carefully and observe these precautions
Read the other documents provided carefully, including any documents on the CD-ROM
Meanings of the principal symbols
that may be present on your product:
CAUTION! Risk of Danger!
CAUTION! Risk of electric shock!
Refer to this safety datasheet and comply
Refer to this safety datasheet, to the user
with the precautions for use.
manual and comply with the precautions for use.
Current clamp: Can be applied to or
Current clamp: Do not apply to or remove from
removed from non-insulated or bare
conductors at dangerous voltages.
conductors at dangerous voltages.
In the European Union, this product is
The CE marking indicates compliance
subject to selective collection in accordance
with the European WEEE directive. Do not
with the European "Low Voltage", "EMC",
"WEEE", and "RoHS" directives.
dispose of it as ordinary waste; contact the
manufacturer
for
information
about
collection points.
Earth
Do not dispose of the batteries as ordinary
waste; take them to a collection point.
Double insulation
Conditions of use
Temperature, Humidity: Comply with the values stated in the user manual.
Altitude : 2 000 m
Pollution degree : 2
Precautions for use
These safety instructions must be respected to assure the personal safety and the environment of use. If
you do not comply with them, there is a risk of electric shock, explosion or re.
If you use these instruments other than as speci ed or without observing the elementary safety rules, the
protection they provide may be compromised, endangering you.
The safety of any system which may include these leads or accessories is the responsibility of the
assembler of the system.
Each time before use, always check that the insulation of the leads or accessories is in good
condition. Any element whose insulation is damaged (even partially) must be removed from use and
scrapped. A change of color of the insulating material is an indication of deterioration.
The steady-state voltages, currents, and measurement categories are marked on the instruments, on
the cords, and on the accessories. Comply with these values.
Use speci c individual safety protections when hazardous live parts can be accessible in the
installation where the measure is performed
Before using your instrument, check that it is in
good working order (for example, by measuring a
known dangerous voltage).
If the manual states how to replace the fuse(s) of your instrument, use only the recommended fuses.
Before replacing the batteries (rechargeable or not), disconnect the leads of your instrument.
The use of a measurement instrument, a lead or an accessory with a lower
category or voltage downgrades the use of the assembly (instrument + lead +
accessory) to the lowest category and/or operating voltage.
Using a measuring instrument in a category II or III or IV environment can be dangerous. In such
measurement environments, the operators must be trained and/or accredited and/or informed of the
safety measures to be taken.
Measurement categories:
CAT II:
Measurement category II is for measurements performed on circuits directly connected to the
low voltage installation
Examples: measurements on household appliances and portable tools.
CAT III:
Measurement category III is for measurement performed in the building installation
Examples: distribution boards, circuit-breakers, machine or industrial equipment with permanent
connection to the xed installation.
CAT IV:
Measurement category IV is for measurements performed at the source of the low-voltage installation.
Example: meters and measurements on primary overcurrent protection devices and ripple
control units.
Cleaning
Disconnect the leads or the test accessories
Use a soft cloth, dampened with soapy water. Rinse with a damp cloth and dry rapidly with a dry
cloth or forced air. Do not use alcohol, solvents, or hydrocarbons.
Do not modify the leads or accessories. Any non-compliant repairs can cause risks of electric shock
or burns.
1
Un C.A 6532 o un C.A 6534 según el modelo pedido.
2
Dos cables de seguridad acodados-rectos (rojo y negro).
3
Una pinza cocodrilo roja.
4
Una punta de prueba negra.
5
Dos sujetacables (rojo y negro).
6
Seis pilas LR6 o AA.
7
Una bolsa de transporte y de uso manos libres.
8
Un CD con los manuales de instrucciones (un archivo por idioma).
9
Una ficha de seguridad en varios idiomas.
10
Una guía de inicio rápido en varios idiomas.
11
Un CD con el software MEG.
1. PRESENTACIÓN
11
5