1.1 Scope of delivery
– Compressor with instruction manual
– Documents accompanying compressed air
vessel
– Rubber dampers
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must not be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must not be sucked in!
1.3 Technical data
see Figs. 1a ...1d
1.4 Components
01
Compressor unit
02
Intake filter
03
Oil filler plug
04
Mini ball valve (oil drain)
05
Oil inspection glass
06
Pressure pipe
07
Check valve
08
Vessel
09
Ball valve at condensate drainage point
10
Pressure switch with ON/OFF switch
11
Safety valve
12
Pressure gauge (vessel pressure)
13
TÜV test flange
14
Electric motor
15
Cradle
16
V-belt
17
Belt guard grating
18
V-belt disc
19
Fan wheel
21
Silencer
22
Ball valve
1
23
Rubber dampers
1
1.5 Maintenance
1
1.5.1
Clean the silencer insert
1
1. Unscrew silencer cover.
1
2. Pull out silencer insert and clean in soapy
1
water (max. 50°C).
3. Slide insert into position, screw on si-
lencer cover.
If the insert can no longer be cleaned
properly, replace the complete silencer
unit.
1.5.2
Checking, setting and adjusting
the V-belt tension
Checking V-belt tension:
See instruction manual, part 2.
Setting/Adjusting V-belt tension:
1. Slacken counternut and remove.
2. Slacken second nut and slide drive motor
towards power unit. (Fig. 7b)
3. Remove old V-belt and replace with new
V-belt.
4. Tighten nut until V-belt tension is cor-
rect.
5. Lock counternut.
6. Attach the belt guard grating again using
the mounting plugs.
1.6 Vessel inspections
An informal inspection book (collection of all
documents related to the vessel including in-
spection documents from the "approved test
centre") must be compiled for the vessel.
Register the vessel with an "approved test
centre", stating this data. The centre initiates
and certifies an installation check by an
authorised expert and specifies the inter-
vals for repeat inspections.
It is essential to retain vessel documents
included in the delivery (= certification
documents) and inspection documents for
the entire service life of the vessel. The
statutory specified inspections must be
arranged in accordance with the applica-
ble regulations of the respective country
in which the vessel is used.
GB
UNM STL 5,5 kW
II/1

Publicidad

loading