11. Troubleshooting
Fault
Engine does not start
Generator has too little or no voltage Controller or capacitor defective
12. Maintenance schedule
Regular service period
Perform at every indicated month
or operating hour interval,
whichever comes first.
ITEM
Engine oil
Air cleaner
Spark plug
Spark arrester
Valve clearance
Combustion chamber Clean
Fuel tank and filter
Fuel tube
Remark:
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, Refer to the manual for service procedures.
Failure to follow this maintenance schedule could result in non-warrantable failures.
Oil shortage cut-out has not responded
Spark plug fouled
No fuel
Battery voltage too low
Overload cut-off has triggered
Air filter dirty
Each
use
Check level
O
Change
Check
O
Clean
Check-adjust
Replace
Clean
Check-adjust
Clean
Check
Cause
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / check the petrol cock
Charge the battery
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
First
Every
month
3
or
months
20 Hrs.
or
50 Hrs.
O
O (1)
After every 300 hrs. (2)
Every 2 years (Replace if necessary) (2)
16
Remedy
Every
Every
6
year
months
or
or
200 Hrs.
100 Hrs.
O
O
O
O
O (2)
O (2)

Publicidad