INSTRUCTIONS FOR USE
FUSE CHECK/REPLACEMENT
1. Turn the ignition key (A, Figure. 26) to "0".
2. Disconnect the power supply cable (C, Figure. 26) from the
electrical mains.
3. Remove the screws (C .Figure27) on control panel (D), then
turn over the PCB to find the fuse (A, B, Figure 27).
4. Check/replace the following fuses:
A) F1 fuse, low power circuit fuse:(5A)
B) F3 fuse, Brush release fuse: (20A)
B) F3 fuse, Brush fuse: (5A)
5. Perform steps 1 to 3 in the reverse order.
6. Check/press down or replace the following breakers:
E) F5breaker, vacuum motor circuit breaker: (30A)
F) •F4 breaker, traction system circuit breaker: (12A) (*)
(only for disc machine)
•F4 breaker, traction system circuit breaker: (17A) (*)
(only for orbital machine)
G) F2breaker, brush motor circuit breaker: (30A)
(*): Only for machine with traction
(only for disc machine)
(only for orbital machine)
A
B
C
VACUUM TRACTION BRUSH
E
23
ENGLISH
Figure 26
A
B
C
D
F
G
Figure 27