Fault
The heater triggers a
fault; the red lamp on
the operating panel
lights up.
The heater burns too
much gas.
The heater cannot be
switched off with the
switch.
Record the maintenance details in table A in
the annex at the back of this manual.
7
SPARE PARTS
Contact the dealer for the use of spare parts.
8
TECHNICAL INFORMATION
For technical specifications, see table B
in the annex at the back of this manual.
AGA 111
Cause
10 The pressure switch
does not switch the
heater off.
11
The pressure switch is
defective.
12 The ignition is not func-
tioning.
13 There is a leak between
the gas cock and the
gas regulator block.
14 The gas regulator block
does not shut off.
40.020.955 - rev. 05 - 2017
Solution
Check if the combustion air
fan is rotating.
Check if the suction grid is
dirty.
Check if the supply of com-
bustion air is sufficient.
Check the pressure switch
and replace if necessary.
Check the connection
between the transformer and
the electrode for a short cir-
cuit.
Remove any short circuit that
is found.
Check the setting of the elec-
trode, see fig. 8.
Shut off the gas supply.
Repair the leak.
Shut off the gas supply and
let the flame burn out.
Disconnect the mains con-
nection.
Check the gas regulator
block.
English
Action
User
User
User
Dealer
User
User
User
Dealer
User
User
Dealer
21