This appliance complies with the following
E.E.C. Directives:
- 87/308 EEC of 2/6/87 relative to radio interference
suppression.
- 73/23 EEC of 19.2.73 (Low Voltage Directive) and
subsequent modifications;
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
Door reversibility
The appliance's door has been locked in position for
transport by means of pins on both sides. According
to the door opening direction, remove relevant pins at
the top and at the bottom.
D163
Warning!
If the ambient temperature is cold (i.e. in
Winter), the gasket may not fit perfectly to the
cabinet. In that case, wait for the natural fitting
of the gasket or accelerate this process by
heating up the part involved with a normal
hairdrier.
All manuals and user guides at all-guides.com
A
B
20
Instructions for totally built-in
appliances
Dimensions of the recess
Height of housing
Depth of housing
Width of housing
PR 32
1. It is necessary that the niche is provided with a
conduct of ventilation having the following
dimensions:
Depth 50 mm
Width 540 mm
D526
For safety reasons, minimum ventilation must be
as shown in Fig.
Attention: keep ventilation openings clear of
obstruction.
D132
2. Apply joint the sealing strip as shown in figure.
mm 880
mm 550
mm 560
880
50 mm
min.
200 cm
2