MAINTENANCE
Before carrying out any maintenance operation on the refrigerator, take the power cable out of its
socket.
CLEANING
• Regularly clean the inside and outside of the refrigerator using only warm water and a neutral detergent.
• After washing, rinse with clean water and dry thoroughly using a soft cloth.
• Do not use the following: special glass and mirror cleaning products, liquid, powder, or spray detergents,
alcohol, ammonia or abrasive products.
• When the refrigerator is not being used, it is advisable to clean the inside thoroughly and leave the door
half open to ventilate the interior.
SUGGESTIONS
If the device fails to operate or malfunctions, before contacting the support service, ensure that:
a) the feeding voltage is not missing;
b) the voltage is the same as the one shown on the plate;
c) the connections and the polarities are right;
d) the airing grids are not covered over;
e) the refrigerator unit is not near any heat source;
f) the fuse of the feeding line is not blown.
The power supply cable must only be replaced by a qualified technician and in any case by an aftersales
service authorised by the manufacturer.
Indel B is not liable in any way if you do not comply strictly with all the previsions in this manual.
FAULTS
When there is error for the fridge, there will be code on the display. The possible error for each code would
be as follows
ERROR CODE
ERROR TYPE
Battery protection
E1
(The voltage is outside the cut-out setting).
Fan over-current cut-out
E2
(The fan loads the electronic unit with more than 1A
Motor start error
E3
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5
bar)).
Minimum motor speed error
E4
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed
1,850 rpm).
Thermal cut-out of electronic unit
E5
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is high,
the electronic unit will run too hot).
NTC temperature probe failure
E6
(NTC open circuit or short circuit)