TERMINAL BLOCKS DESCRIPTION
TAMPER
Supporting terminals for wiring tampers, if any
G
Output of fuse failure warning (and/or battery low)
Open collector type , provides a negative in warning - max 2 mA
BL
Output of battery low warning
Open collector type , provides a negative in warning - max 2 mA
L
Output of mains presence warning
Open collector type , provides a negative in warning - max 2 mA
CPS
By supplying a negative on this terminal, the battery test function is armed.
This function is possible with the relevant power suppliers (PS515) and is useful
to check the buffer battery efficiency.
POWER
Power supply to devices. Protected by 1A fuses
+BAT-
Buffer battery connection
- + C
Connection to power supplier terminals (PS515)
PS515 Features
PS515 POWER SUPPLIER
The factory setting of voltage drop (14.5V adjustable) takes
account of the 0,6/0,7 V voltage drop at the edges of the
protection diode installed in many alarm control units and
in most ELKRON control units.
(((ELKRON)))
18
+ - C
FUSE
F - 3,15A