HYDRAULIC CONNECTION
•
Water quality necessary for this device: NF-EN-16713-3
•
The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool's hydraulic
•
circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
•
Follow the hydraulic connection order (
•
Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue (stone, soil, etc.).
Step 1 :
Step 2 :
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water flow, which can be more or less important depending on the
degree of humidity. To channel this flow, which can represent several litres of water per day, we recommend you install the provided condensate evacuation
pack and connect it to a suitable water evacuation circuit.
ELECTRICAL CONNECTION
•
Prior to undertaking any intervention inside the HP, it is imperative to disconnect the power supply from the HP; there is a risk
of electrocution that can cause damages, severe injuries and even death.
•
The power supply should match the voltage featuring on the information plate of the HP.
•
The HP must be connected to an earthing connection.
•
The electrical terminal should covered from water with an adapted system (not included).
Only a certifyed electrician can confirm if your electrical installation is in conformity with local law in force.
Power supply must be equipped with grounding, circuit breaker and 30 mA differential protection.
•
The plug provided with the machine is equipped with an additional 10 mA differential security with manual reset button.
•
The heat pump must work in the same time as the water pump.
= water in,
= water out)
- 16 -
> 3,5 m