Descargar Imprimir esta página

Holmatro GCU 50 i EVO 3 Manual página 39

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 94
Best results and longest life of the battery pack are achieved by charging in a dry environment at a
temperature between 18 °C and 24 °C (64 °F and 75 °F).
CAUTION
The battery pack can be damaged if charged at a temperature below 0 °C or above 40 °C
(below 32 °F or above 104 °F).
The SOC indicator on the battery pack will indicate the state of charge of the battery pack when the
SOC indicator button is pushed.
The maximum capacity of the battery pack is only achieved once it has been charged and
discharged several times.
Always charge the battery pack, even if it has only been used for a short time.
The battery pack can remain connected to the battery charger for an indefinite period of time,
because it is protected against overcharging.
NOTICE
When the battery pack is not in use, it is advised to keep it connected to the battery charger
(connected to a power source) at all times. When the battery pack is full, the battery charger
automatically switches on and off at regular intervals to keep the battery level at 100%.
After deep discharge of the battery pack, charge the battery pack for 24 hours. If the battery
pack is not completely charged after 24 hours, contact your local Holmatro dealer.
5.4
Installing the battery pack
Slide the battery pack in the battery pack fitting / adapter fitting until the battery pack lock snaps
tight.
5.5
Connecting to an external power source
See Fig. 5.
Apart from using the battery pack, the tool can also be connected to the mains by the special mains
connector. Use only the original mains connector for this purpose.
Slide the adapter of the mains connector in the battery pack fitting / adapter fitting until the battery
pack lock snaps tight.
Insert the plug of the mains connector into the appropriate power outlet.
5.6
Starting the tool
Operate the on/off switch to activate the tool. The green LED will light and the electric motor runs at
slow speed.
The tool operates if the deadman's handle is turned to position
NOTICE
If the tool is not used, it will switch off after a while. The green LED will blink. Press the on/off
switch 2 times to re-activate the tool.
NOTICE
When the tool is not used for 10 minutes the battery pack will switch off. The green LED will
not light anymore. To activate the battery pack again:
Press the SOC indicator button, or
Operate the on/off switch again, or
Reinstall the battery pack.
GCU 50* (i) EVO 3
All manuals and user guides at all-guides.com
916.001.652_002
or
.
EN
39

Publicidad

loading

Este manual también es adecuado para:

Gcu 50 evo 3