NOTA IMPORTANTE:
Configuración de parámetros por el instalador.
- Para realizar la configuración, ver ANEXO: Configuración asistida por voz en placas
de pulsadores. Instrucción incluida en este equipo.
- También se puede realizar la configuración conectando temporalmente un teclado
ref. 7439, descargar el manual de Programación Placas Direct Video Duox, cod.
970052, en www.fermax.com.
MASTER Panel:
· Apartment terminals programming are always done from the panel activated as
MASTER.
· Any installation can only have one MASTER panel at a time, whether a single or
multiple block installation, once configured as a sub-block, block or general
entrance.
· A street panel is configured as a MASTER via the SW1 amplifier button. If the SW1
button is pressed 3 times quickly, it is activated as a MASTER panel and a
confirmation tone sounds (beep-beep), after 2 seconds.
· When a panel is selected as MASTER, it notifies the rest of the situation and if
another was previously configured, it would automatically stop being so.
· If there are various blocks in an installation, we recommend using the general
entrance panel as MASTER since it allows you to program all of its telephones/
monitors.
· Once having completed the terminal´s configuration, we recommend deactivating
the MASTER panel to avoid accidentally reprogramming terminals.
· The panel deactivates itself from master mode following the same activation
procedure: 3 quick presses of the SW1 button. A deactivation tone sounds (bop),
after 2 seconds.
Configuration - Programming the Amplifier
The DUOX amplifier can be configured to allow for the operation as a general
entrance, block entrance or sub-block entrance.
· The DUOX system uses 6 digit house terminal addresses.
· These call code digits are organised as follows: BBSSNN:
- BB: indicates the Block number, (from 00 to 99).
- SS: indicates the sub-Block number, (from 00 to 99).
- NN: indicates the sub-Block house number, (from 00 to 99).
You do not have to segregate the installation according to this hierarchy since the
system adapts to the installation´s needs.
IMPORTANT NOTE:
Configuration of the installer's parameters..
- For configuration see ANNEX: Voice assisted configuration in button panels.
Instructions included with this equipment.
- You can also configure it by temporarily connecting a keypad ref. 7439, download the
Direct Video Duox Panel Programming Manual, cod. 970052, at www.fermax.com.
Pag 12