Parameters
Position on
menu
structure
DST
Date and Time Daylight Summer Time change between Summer
OFF Screen
Display
Period
Sensor
Installation >
Calibration
Sensor
Sensor
Installation >
Regulation
Regulation
C-IR 20 – 6721851970 (2022/12)
Description
and Winter
Yes- automatic change according to date
No - no daylight summer time automatic change
This parameter allows the user to set when the
display must be completely shut off.
Default OFF Screen Periodis between 20 pm to 7
am.
The calibration must be done after one day of
working with the same setting temperature in
accordance with the following description:
▶ Put a thermometer in the room at 1,5 m
distance from the floor and check the real
temperature in the room after one hour.
▶ Then, select the sensor you wish to calibrate.
▶ Use the (-) or (+) keys to enter the real value
Only the heating element driven by the
thermostat must be used during the complete
step of the calibration.
Calibration can be erased by using the RESET
function.
Air: only internal sensor is used, no floor
limitation
Parameter's precision
37