USER MANUAL
PWT12IEC
3
CONNECTIONS AND OPERATING ELEMENTS
1. AC INPUT
IEC connection for the power supply of the unit. A suitable mains cable is included in the scope of delivery.
2. POWER
Rocker switch for switching the device on and off. The switch has an indicator light. This lights up as soon as the unit is
correctly connected to the power supply and switched on.
3. DC OUTPUT
Non-isolated 9 V DC output with up to 2000 mA output current for effects units with high current requirements and
external power supplies (e.g. PWT04) that do not require an isolated and filtered power supply.
4. USB
One USB-C and USB-A port each with up to 18 watts total power for charging smartphones, tablets and the like.
5. OUTPUT 1 AND 2
Two isolated DC voltage outputs with potentiometers for a continuously adjustable output voltage from 6 V to 18 V and
up to 250 mA output current. Always set the required voltage BEFORE connecting the corresponding effect device.
6. OUTPUT 3 TO 6
Four isolated DC outputs with 9 V output voltage and up to 100 mA output current each.
7 OUTPUT 7 TO 10
Four isolated DC outputs with 9 V output voltage and up to 250 mA output current each.
8. OUTPUT 11 AND 12
Two isolated DC outputs with 9 V output voltage and up to 500 mA output current each.