TESTING THE ANTIMICROBIAL
SOLUTION
Test MultiMicro 200 solution to verify proper
dilution through the Orbio dispenser. This
procedure will test both the bottle and bucket fill
metering tips.
Tools required: Orbio Chlorine Test Paper and 2
clean 240 cc (8 oz.) containers.
Orbio Chlorine Test Paper
If the solution test paper does not indicate 200
ppm contact technical support. Discard solution
that does not pass this test procedure.
1. Fill one container with solution from the bottle
fill tube.
1
2. Fill the second container with solution from
the bucket fill tube.
2
Multi CLEANER
Multi 200
Micro
OS3 DM20036 (3−2014)
Multi CLEANER
Multi 200
Micro
OPERATION EN
3. Using a chlorine test strip for each container,
dip and remove quickly.
3
4. Blot immediately.
4
5. Compare to color chart on test paper
container. "200" indicates correct
concentration.
5
10
50
OK
100
200
23