connect to auxiliary faucet
Connect Water Lines
*Note: System will NOT operate without Restrictor.
Note: Tubing lengths should allow for the removal of the assembly from the mouting screws for servicing. If tubing lengths
are shortened for neater appearance, it may be necessary to keep the assembly on the mounting screws for service.
Note: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of
saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of
Massachusetts before proceeding with the installation.
Air Gap from Faucet to RO Assembly
Locate Membrane Drain port at bottom of
Membrane.
Take Elbow Fitting and press down into Membrane
drain port to connect the fitting.
Locate the ¼" red tubing attached to the Air Gap
barb on the Auxiliary Faucet body.
Measure the length of ¼" red tubing necessary to
connect to the membrane drain port. The tubing
must be straight as possible with no loops, dips, low
spots or kinks.
Cut the ¼" red tubing squarely to correct length
with a utility knife.
Insert the restrictor into the end of the red tubing.
Insert the red tubing into the open end of the Elbow
Fitting.
Gently tug on the red tubing to ensure it is firmly
connected to the Elbow Fitting.
Connect 3/8" Red Tube from Reverse Osmosis Faucet to Drain Adapter
Locate 3/8" Red Plastic Tubing already attached to
RO Faucet Body.
The other end needs to be attached to collet on sink
Drain Connector.
Cut 3/8" Red Plastic Tubing as needed to route in as
straight of a run as possible, without loops, dips, low
spots, or kinks.
Cut end of 3/8" Red Plastic Tubing square with a
sharp utility knife.
Insert all the way into fitting approximately 1" until
it stops.
Pull on tube to be sure it is held firmly in fitting.
NOTICE: Drain line into drain must be level.
14
Step 6
<< Step continued from previous page
1/4"
water
line
*RESTRICTOR
Elbow
Fitting
Drain
Port