Descargar Imprimir esta página

Mc Haus 1230011 Manual Del Usuario página 49

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MAIN MODALITIES
auto
Mode
auto
1.
Once the Operation mode
is selected, the internal temperature sensor automatically selects either
cool
fan
the
or
mode.
2.
When the ambient temperature is > 24ºC the device will automatically select the mode
3.
Cuando la temperatura ambiente es < 24ºC el dispositivo seleccionará automáticamente el modo
dry
Mode
1.
The overhead centrifugal fan will run at low speed and the speed can not be adjusted.
2.
The compressor. The downward centrifugal fan will stop after running 8 min. Its operation will start again
after 6 min.
3.
The device adopts constant temperature dehumidification mode and the temperature setting is not
effective.
cool
Mode
1.
When the room temperature is higher than the set temperature, the compressor starts running.
2.
When the room temperature is lower than the set temperature, the compressor stops and runs at the
automatic speed.
fan
Mode
1.
The up centrifugal fan runs at the set speed and the compressor does not run.
2.
The temperature setting is not effective.
heat
Mode
1.
When the room temperature is higher than the set temperature, the unit will stop heating function.
2.
When the room temperature is lower than set temperature, the unit will start heating function.
96
MAIN MODALITIES
Mode
1.
Press the "Timer" button to set the automatic shutdown time while the unit is running.
2.
Press the "Timer" button to set the auto power on time while the unit is ready.
cool
.
The time can be set within a range of 1h to 24h.
fan
.
3.
Press the
Mode
1.
The operation
2.
Press the button
fan will automatically rotate at low speed. The set temperature will increase by 1ºC after one hour, and
will increase by 2ºC after two hours. After six hours, the unit will stop operating.
Mode
1.
When this mode is active, the wings will automatically swing up and down.
Press the button a second time to turn off this mode.
or
button to increase or decrease by 1 hour by pressing 1 time..
ais effective when the unit is in mode
cool
in mode
, then the unit will operate in standby mode and the up centrifugal
WARNING:
The main control board has memory function, when the unit is ready to run, but in stop state, the
main control board can memorize the initialization of working mode. When the device is active, it
will work with the same working mode as the last time, without resetting the working mode again.
This condition is not available when the unit is in mode
cool
.
auto
.
97