Descargar Imprimir esta página

Vortice 17175 Manual De Instrucciones página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
ENGLISH
Selecting the operating mode
set the dip-switch SW2 indicated in the figure:
Int.2=ON; Int.3=OFF; Int.4=OFF
set the dip-switch SW2 indicated in the figure:
Int.2=OFF; Int.3=OFF; Int.4=OFF
Setting the V1 and V2 values
The appliance leaves the factory with default nominal settings V1=VMIN, V2=VMAX
Values V1 and V2 can be adjusted as follows:
To set the trickle and boost variable speeds.
Set the SW2 dip-switch as follows:
1 to off, 2 to off, 3 to off, & 4 to on
When the power is switched on, the trickle speed (V1) runs at the fac-
The trickle / default speed (V1) can be adjusted to the desired flow
rate using the potentiometer.
A small flat head screw driver will be required.
The trickle (V1) speed should set 100 rpm lower than the desired
The trickle speed value can now be saved by switching 1 to on.
The boost (V2 default) can now be adjusted
Once the desire boost flow rate is achieved it can be set
To complete the commissioning and prevent tampering
14
Two-speed mode:
cut off the power supply
Adjustable speed mode:
cut off the power supply
Isolate the power
tory default speed.
boost (V2)
using the potentiometer.
by switching 1 to off.
Isolate the power
set 1, 2, 3 & 4 to off
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4

Publicidad

loading

Este manual también es adecuado para:

Lineo 315 quiet esLineo 250 quiet es17176