AC24NE
LED Display
De nition
Auto-closing
F9
Reverse mode in
F10
opening
Reverse point on
F11
opening
F12
Modo de reversa en
cierre
F13
Punto de reversa en
cierre
Velocidad de marcha
F14
Tiempo de ignorar los
F15
valores de sensibilidad
durante la marcha
Parameter
F9-0
Function OFF
F9-1
3 sec
F9-2
10 sec
F9-3
20 sec
F9-4
40 sec
F9-5
60 sec
F9-6
120 sec
F9-7
180 sec
F9-8
300 sec
F10-0
disabled
F10-1
2 seconds
F10-2
Total reverse
F11-1
It falls back within 95% of
route; stops within 5%.
F11-2
It falls back within 90% of
route; stops within 10%.
F11-3
It falls back within 85% of
route; stops within 15%.
F11-4
It falls back within 80% of
route; stops within 20%.
F11-5
It falls back within 75% of
route; stops within 25%.
F12-0
Disabled
F12-1
2 seconds
Total reverse
F12-2
F13-1
It falls back within 95% of
route; stops within 5%.
F13-2
It falls back within 90% of
route; stops within 10%.
F13-3
It falls back within 85% of
route; stops within 15%.
F13-4
It falls back within 80% of
route; stops within 20%.
F13-5
It falls back within 75% of
route; stops within 25%.
F14-1
Full speed
F14-2
Average speed
F14-3
Slow speed
F15-0
After starting the engine 0 seconds
F15-1
After starting the engine 0.5 seconds
F15-2
After starting the engine 1.0 seconds
F15-3
After starting the engine 1.5 seconds
F15-4
After starting the engine 2.0 seconds
Table
1. Auto-close mode activates when the
gates move to the end position or
stopped manually. If the transmitter,
push button, or the key selector is
activated before the auto-close
counting, the gate will close
immediately.
2. The factory setting is "F9-0".
1. The original parameter is "10-0".
1. The original parameter is "11-3".
2. Reverse logic refers to parameter
10
3. Reverse speed refers to parameter
6.
1. The original parameter is "12-2".
1. The original parameter is "13-3".
2. Reverse logic refers to parameter
10
3. Reverse speed refers to parameter
6.
1. The original parameter is "14-1".
1. The original parameter is "15-4".