MAINTENANCE
Cleaning the Drain Pump Filter
Warning!
•
Make sure that the machine has finished the washing cycle and is
Switch it off and unplug it before cleaning the drain pump filter.
• Be careful of hot water. Wait for water cooling down. Risk of scalding!
• Clean the filter periodically every 3 months to ensure the normal operation of
the appliance.
Open the lower cover
cap
Open the filter by turning
to the counter clockwise
Caution!
•
Make sure that valve cap and emergency drain hose are reinstalled
properly, cap plates should be inserted aligning to hole plates
otherwise water may leak.
Some machines don't have emergency drain hose, so step 2 and step 3
•
can be skipped. Rotate lower cover cap directly to make water run into
basin.
•
When the appliance is in use and depending on the programme
selected there can be hot water in the pump. Never remove the pump
cover during a wash cycle, always wait until the appliance has finished
the cycle, and is empty. When replacing the cover, ensure it is securely
re-tightened.
1
Rotate 90°C and pull
out the emergency
drain hose, and take off
the hose cap
4
Remove extraneous
matter
2
Emergency
drain hose
5
34
empty.
After water runs out,
reset the drain hose
Close the lower
cover cap
3
6
V .1