NORMAL OPERATION
After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous stresses
and deformations (according to the instructions on paragraph TECHNICAL DESCRIPTION). You should always use the product with the
door closed in order to avoid damages due to overheating (forge effect). The inobservance of this rule makes the warranty expire.
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the fuel or for
removing the ashes, while during the operation and the rest, the door of the hearth must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is allowed under
supervision.
! IMPORTANT: For safety reasons the door of the hearth can be opened only for the loading of the fuel. The hearth door must always
remain closed during operation or rest.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be
opened according to the calorific need. The best combustion (with minimum emissions) is reached when, by loading the wood, most
part of the air for combustion flows through the secondary air register.
Never overload the appliance (see the hourly wood load in the table here below). Too much fuel and too much air for the combustion
may cause overheating and then damage the stove. You should always use the appliance with the door closed in order to avoid
damages due to overheating (forge effect). The inobservance of this rule makes the warranty expire.
The adjustment of the registers necessary to reach the rated calorific yield with a depression at the stack of 12 Pa 1,2mm of column of
water) is the following one: see chapter TECHNICAL DESCRIPTION. The appliance works as an intermittent operating appliance.
Besides the adjustment of the air for the combustion, the intensity of the combustion and consequently the thermal performance of the
device is influenced by the stack. A good draught of the stack requires a stricter adjustment of air for combustion, while a poor draught
requires a more precise adjustment of air for combustion.
To verify the good combustion, check whether the smoke coming out from the stack is transparent.
If it is white, it means that the device is not properly adjusted or the wood is too wet; if instead the smoke is gray or black, it signals that
the combustion is not complete (it is necessary a greater quantity of secondary air).
! WARNING: When fuel is added onto the embers in the absence of a flame, a considerable amount of fumes may develop. Should this
happen, an explosive mixture of gas and air may form, and in extreme cases an explosion may occur. For safety reasons it is advisable to
perform a new lighting procedure with the use of small strips.
OPERATION IN TRANSITION PERIODS
During transition periods when the external temperatures are higher, if there is a sudden increase of temperature it can happen that
the combustion gases inside the flue cannot be completely sucked up.
The exhaust gases do not come out completely (intense smell of gas). In this case, shake the grating more frequently and increase the
air for the combustion. Then, load a reduced quantity of fuel in order to permit a rapid burning (growing up of the flames) and the
stabilization of the draught. Then, check that all openings for the cleaning and the connections to the stack are air-tight. In case of
doubt, DO NOT operate the product.
MAINTENANCE AND CARE
Check the external air intake, by cleaning it, at least once a year. The stack must be regularly swept by the chimney sweeper.
Let your chimney sweeper in charge of your area check the regular installation of the device, the connection to the stack and the
aeration.
! IMPORTANT: THE MAINTENANCE MUST BE CARRIED OUT ONLY AND EXCLUSIVELY WITH COLD DEVICE.
You should only use spare parts approved and supplied by
Producer.
Please contact your specialized retailer if you require spare parts.
YOU MUST NOT MAKE ANY CHANGES TO THE DEVICE!!!
GLASS CLEANING
Thanks to a specific inlet of secondary air, the accumulation of dirty sediments on the glass-door is reduced with efcacy. Nevertheless
this can never be avoided by using solid fuels ( particularly wet wood ) and it has not to be understood as a defect of the appliance.
! IMPORTANT: The cleaning of the sight glass must be carried out only and exclusively with cold device to avoid the explosion of the
same. For the cleaning, it is possible to use specific products or a wet newspaper paper ball passed in the ash to rub it. Do not use
cloths, abrasive or chemically aggressive products by cleaning the hearth glass.
The correct lighting phase, the use of proper quantities and types of fuels, the correct position of the secondary air regulator, enough
draught of the chimney-flue and the presence of combustion air are the essential elements for the optimal functioning of the appliance
and for the cleaning of the glass.
GB