Descargar Imprimir esta página

Tooland AC30 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
3.
General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
Protect this device from shocks and abuse. Avoid brute force when operating the device.
Protect the device against extreme heat, dust and moisture.
Familiarise yourself with the functions of the device before actually using it.
All modifications of the device are forbidden for safety reasons.
Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the
dealer will not accept responsibility for any ensuing defects or problems.
4.
Overview
Refer to the illustrations on page 2 of this manual.
1
2
3
4
5
6
7
8
9
10
5.
Preparation
Always check the condition of the cables and clamps before using the battery charger. Do not use
when damage is noticed!
Refer to the illustrations on page 2 of this manual.
Disconnect the battery from the vehicle before charging. To do this, first remove the negative pole
connection, and then proceed with the positive pole connection.
Clean the poles with a steel brush or sandpaper.
Open the filler caps and check the level of the battery acid. When necessary, add distilled water (liquid level
must be ±1cm below fill opening).
Note: battery acid is corrosive; avoid contact with skins or clothing. Any spills should be washed off
immediately with plenty of water. Consult a doctor when necessary.
Open all filler caps and leave them open during charging, unless the battery has special safety features
built-in (e.g. spark arrestor). Refer to the data sheet of the battery or consult a specialist to find out.
Make sure the battery charger is not connected to the mains [10].
Verify whether the battery is a 12 V or 24 V type. Connect the negative (red) lead with the appropriate
terminal: +12 V [9] for 12 V batteries, +24 V [8] for 24 V batteries. The terminal knob must be screwed
tightly on the terminal.
Connect the positive clamp of the battery charger (red) with the positive pole (+) of the battery. Make
sure the clamp is secured tight.
Connect the negative clamp of the battery charger (black) with the negative pole (-) of the battery. Make
sure the clamp is secured tight.
Plug the battery charger into a suitable mains outlet.
V. 03 – 09/10/2017
AC30
current meter
fuse 30 A
fuse 5 A
1/2 switch
MIN/BOOST switch
ON/OFF switch
DC output "-"
DC output "+24 V"
DC output "+12 V"
AC input
4
©Velleman nv

Publicidad

loading